135 litres is the number everyone quotes. For a city this size, it is the floor.

Multiply people by litres per day, then by the days you must survive between refills. Both multipliers are published as ranges, both are commonly taken at the low end, and the errors do not cancel — they compound, in the direction of a tank that runs dry.

0
Litres per person per day — a band floor, not a design value
0
Top of the published band for a city over a million
0
Factor the supply interval alone can swing your capacity
0
Litres in a cubic metre — the only exact figure here
In this guide — 6 sections
  1. What a sump is for
  2. The interval decides the size
  3. The per-person figure is a band
  4. Litres into dimensions
  5. Construction, and your own number
  6. Sources and FAQs
Direct answer

Multiply the number of people by daily consumption per person, then multiply that by the number of days you need to survive between refills. The interval matters more than the family size: two identical households need very different sumps if one is supplied daily and the other every five days. But take care with the per-person figure too. The widely quoted 135 litres is the bottom of the published band for a large city and the top of the band for a small town — for a city of over a million the indicated range is higher, and Tamil Nadu prescribes its own minimums. Size on the band that fits your city, not on the number everyone repeats.

Where the sump sits, how it is piped and what the drawings must show is covered in our guide to plumbing and drainage drawings. This page is only about capacity — how many litres, and what that becomes in metres. Buildiyo is on +91 70921 66366, +91 70921 66266 and +91 70921 66177.

01 / 6
Two tanks, two jobs

What a Sump is for

Definition — Underground sump

A water storage tank built below ground level, usually in reinforced concrete, that receives water from the mains or a tanker and feeds the overhead tank by pump. Its purpose is to carry the household through the gap between one supply and the next. The overhead tank is a different device solving a different problem: it provides pressure and buffers against the pump being off, and is typically sized for around a day of use rather than for the supply interval.

These two are sized by different logic, and treating them as one pool is how a house ends up with an overhead tank that is far too large and a sump that is too small.

Swipe or scroll to see the full table →

 Underground sumpOverhead tank
Protects againstThe mains or tanker not arrivingThe pump being off, and low pressure
Sized byDaily demand multiplied by supply intervalRoughly a day of use, plus pump cycling
Typical positionBelow ground, near the inlet pointOn the roof or a structure above the house
Structural concernWater pressure outward, soil and water pressure inwardDead load on the slab below it
If undersizedYou run dry between suppliesThe pump runs more often than it should
If oversizedCost, space, and water standing longerSignificant load on the structure, and stale water

An oversized overhead tank is not a free safety margin — water is heavy, and the load sits on your roof slab. Capacity above a day or so belongs in the sump, where the ground carries it.

02 / 6
The dominant multiplier

The Interval Decides the Size, not the family

Same family, very different tank

Take a four-person household at 150 litres per person per day, which is the lower end of the published range for a city of over a million. That is 600 litres a day. Refilled daily it needs about 600 litres of storage; every three days, about 1,800; every five days, about 3,000; every seven days, about 4,200. Nothing about the family changed. The requirement moved by a factor of seven purely because of how often the water arrives — and that is the one variable no published table can give you, because it varies by street, by season, and by whether you are on mains, borewell or tanker. Ask three neighbours how often they are supplied, and what happens in a dry spell, before you ask anyone what size to build.

03 / 6
A band, not a number

The Per-Person Figure is a range

Indian water supply schemes are designed around a figure in litres per capita per day, and almost every sump guide quotes 135. That figure is real but it is being used wrongly. In the published norms it is a band boundary, not a universal design value.

Where 135 actually sits in the norms

The design figure varies by settlement class. For towns under about a hundred thousand people the indicated range runs to roughly 135 at its top, with lower values where sewerage is partial or drainage is septic-tank based. For cities between about a hundred thousand and a million, the range starts at roughly 135 and runs to about 150, with sewered areas at the higher end. For cities above a million, the range is higher again — roughly 150 to 200, with commercial and institutional demand included. So 135 is the ceiling of the small-town band and the floor of the mid-size band. It is not the sewered-area figure, and for a city the size of Coimbatore it is below the published range entirely. Note also that several states, Tamil Nadu among them, prescribe their own minimums through their state water supply manuals, and the guidance is to use the higher of the state and national figures. The manuals are also under revision, so confirm the figure that applies to your own scheme rather than taking any number, including these, as settled.

Swipe or scroll to see the full table →

HouseholdDaily at 135Daily at 1503-day gap at 1505-day gap at 150
3 people405 L450 L1,350 L2,250 L
4 people540 L600 L1,800 L3,000 L
5 people675 L750 L2,250 L3,750 L
6 people810 L900 L2,700 L4,500 L
8 people1,080 L1,200 L3,600 L6,000 L

The two daily columns differ by about eleven per cent, and at the top of the large-city range the gap against 135 is nearer half again. These are total storage requirements before any reserve margin, and before the split between sump and overhead tank. Where you have a metered reading from a previous home, that beats any published figure.

Both multipliers are habitually read low, and the three errors multiply rather than cancel

The usual framing treats this as one solid half and one shaky half: the per-person figure is published and therefore reliable, the supply interval is local and therefore the problem. That split is wrong. The per-person figure is not a point value at all. It is a band that moves with settlement class and sewerage, with a state overlay that can raise it, so the supposedly solid half carries a spread from roughly 135 to 200 depending on which band applies to you. Now look at the direction each error runs. A household estimating its supply interval estimates from recent experience, meaning the normal weeks rather than the dry spell — the dry spell being precisely the event you are building storage for. A household picking a per-person figure takes the lowest urban number in circulation, because that is the one everybody repeats. And a household converting litres into a tank rounds down to the nearest familiar capacity. Three independent judgements, all biased the same way. They do not cancel; they multiply. Here is the concrete version. Four people, five-day interval. At 135 litres you get 2,700 and buy the three thousand litre tank feeling you have margin. At 150 you get exactly 3,000 — same tank, no freeboard, no reserve at all. At the top of the band you get 4,000 and needed the five thousand. One whole tank size, created by which end of a published range you read.

Run it at both ends of the band

One Tank Size Hangs on Which Figure You Read

Four people on a five-day gap: 2,700 litres at 135, exactly 3,000 at 150, 4,000 at the top of the range. Size against the worst interval your street reports, not the usual one.

04 / 6
The one exact conversion

Turning Litres into dimensions

This part is not a range. One cubic metre holds exactly a thousand litres, so a five thousand litre sump needs five cubic metres of effective internal volume — effective meaning below the outlet and above the floor, excluding the freeboard you leave at the top and any dead volume the pump cannot draw.

Swipe or scroll to see the full table →

Effective capacityVolume neededShallower optionDeeper option
2,000 litres2.0 m³2.0 × 1.3 × 0.77 m1.5 × 1.1 × 1.21 m
3,000 litres3.0 m³2.5 × 1.5 × 0.80 m1.8 × 1.2 × 1.39 m
5,000 litres5.0 m³2.5 × 2.0 × 1.00 m2.0 × 1.5 × 1.67 m
7,500 litres7.5 m³3.0 × 2.5 × 1.00 m2.5 × 2.0 × 1.50 m
10,000 litres10.0 m³4.0 × 2.5 × 1.00 m2.5 × 2.0 × 2.00 m

Internal effective dimensions. Add freeboard above the top water level, and wall and base thickness outside these figures — the excavation is larger than the tank. Your structural engineer sizes the walls, base and cover slab for your soil and water table, which in parts of this region is high enough to matter.

Deeper is not free

The same capacity can be a long shallow tank or a deep narrow one, and they are different constructions. Going deeper means more excavation, higher soil and groundwater pressure on the walls, and a harder job for anyone cleaning it. Going wider means more plan area, which may be exactly what a tight plot does not have. Where the water table is high, depth also raises the risk of uplift on an empty tank. A full tank pushes outward; an empty one in wet ground is pushed inward and upward, and both load cases belong in the design. Decide the shape with your engineer rather than by capacity alone.

05 / 6
Seven steps, six details

Working Out Your Own Number, and building it properly

  1. Count the people, including the ones who will live there laterA house built for four that will hold six in five years should be sized for six, because enlarging a sump later means excavating next to a finished house.
  2. Pick a per-person figure from the right bandMatch it to your settlement class rather than defaulting to 135, check whether the state figure is higher, and use your own metered consumption if you have a reading.
  3. Find your supply interval, at its worstAsk neighbours on the same street how often water actually arrives and what happens in a dry spell. Use the worst figure anyone reports, not the average.
  4. Multiply, then add a reserve deliberatelyDaily demand times interval, plus a margin you choose for a reason rather than by rounding to a familiar tank size.
  5. Add non-household uses separatelyGarden, car washing and any planned extension are additions to the base figure, not absorbed by it.
  6. Split between sump and overhead tankRoughly a day in the overhead tank; everything above that below ground.
  7. Convert to dimensions and check the plotA cubic metre per thousand litres, then see whether that footprint fits where you can actually dig — and resist rounding the answer down to fit.
  • Waterproofing on both faces — the tank must keep clean water in and groundwater out. Specify the detail rather than leaving it to site discretion.
  • Access for cleaning — a cover large enough for a person and equipment to get in, positioned where it can actually be opened, and not under a parked car. A tank you cannot clean easily is one that will not be cleaned.
  • Ventilation — a sealed tank with no air path is unpleasant to enter and unsafe to work in. Provide a vent, screened against insects.
  • Inlet and outlet positions — inlet high, outlet above floor level so settled sediment is not drawn into the pump, and arranged so water moves through rather than stagnating in a corner.
  • Overflow — a pipe discharging somewhere harmless and visible, so an overflow is noticed rather than quietly soaking the foundation.
  • Distance from drainage and soak pits — keep the sump well away from any source of contamination, and confirm the separation with your engineer for your plot.

Settle all of this at plan stage. The sump position affects the inlet route, the pump location, the plumbing and the setback space you can still use, and it is cast into the ground early. Soil and water table drive both the structural design and the shape, which our guide to foundations and soil covers, and the cleaning regime belongs in your maintenance schedule from the first year. If you are planning home construction in Coimbatore, bring your supply interval to the first design conversation — it is one of the few site facts that changes the drawing.

06 / 6
Sources & questions

Where to Verify, and what we corrected

What this page rests on, and where we departed from the usual guidance

One figure is exact; the rest are published ranges that need matching to your own case
  • Per-capita design figures come from the national water supply norms, summarised with the current band structure here: a summary of the design norms and the water demand chapter.
  • Where we departed from most guides. They quote 135 litres as the figure for sewered urban areas. On the published bands it is the top of the small-town range and the bottom of the mid-size range, with sewered areas at the higher end of whichever band applies — so for a large city it understates demand.
  • What that changes. Our tables are shown at both 135 and 150 so the sensitivity is visible, rather than presenting one number as the answer.
  • The state overlay. Several states including Tamil Nadu prescribe their own minimums; the guidance is to use the higher of the state and national figures.
  • Revision status. The manuals are under revision, so confirm the figure applying to your scheme rather than relying on any summary, this one included.
  • The only exact number here is the conversion: a cubic metre is a thousand litres.

This article is general guidance. The per-person figures are published planning values rather than measurements of your household, and all dimensions shown are illustrative. Structural design, waterproofing specification and separation distances must come from a qualified engineer for your plot and soil conditions.

What size sump do I need for a house?

Multiply the number of people by daily consumption per person, then by the days between supplies. For a city of over a million, where the published range starts around 150 litres per person per day, a four-person household needs about 600 litres a day — so roughly 1,800 litres of storage on a three-day interval and about 3,000 litres on a five-day interval, before any reserve margin. At the commonly quoted 135 the same household computes to 2,700 litres on five days, which is why the figure you pick matters.

How much water does a person use per day?

The design figure depends on settlement class. Towns under about a hundred thousand sit in a range topping out near 135; cities between a hundred thousand and a million run roughly 135 to 150; cities above a million run roughly 150 to 200, with sewered areas at the higher end of their band. These are municipal design values with headroom built in, and your household’s actual use may be lower or higher depending on garden, vehicles and habits.

Why do most guides say 135 litres?

Because it is the most quoted number in the norms, and it does appear as an urban benchmark minimum. The error is treating it as the sewered-area design value. It is a band boundary — the ceiling for small towns and the floor for mid-size cities — so applying it to a large city uses the bottom of a range as though it were the middle.

How do I convert litres into sump dimensions?

One cubic metre holds exactly a thousand litres. A five thousand litre sump needs five cubic metres of effective internal volume — for example 2.5 m by 2.0 m by 1.0 m of usable depth. Add freeboard above the top water level and wall thickness outside those dimensions, so the excavation is larger than the tank.

Should the sump or the overhead tank be bigger?

Normally the sump. The overhead tank is sized for about a day of use and provides pressure; the sump carries you between supplies. Capacity beyond a day belongs underground, where the ground takes the weight rather than your roof slab.

Is a bigger sump always better?

No, but the errors are not symmetric. Oversizing costs money and plot area once, at construction, and leaves water standing longer between refills. Undersizing costs tanker water and inconvenience every dry season, and the only structural fix is excavating beside a finished house. Size it deliberately for your band and your worst supply interval rather than building the largest tank that fits — or the smallest that the arithmetic just allows.

What is the most commonly missed construction detail?

Access. Sumps are regularly built with covers too small to work through, or that end up under a driveway. Ventilation runs a close second, because a sealed tank with no air path is unsafe to enter.

Do I need to plan for future needs?

Yes, because enlarging a sump later means excavating next to a finished house. Size for the household you expect in five to ten years, and for any extension or garden you intend to add. Add those as separate figures rather than assuming the base calculation absorbs them.

Three errors, one direction

Do Not Round the Answer Down to a Familiar Tank

A low per-person figure, an optimistic interval and a rounded-down capacity all point the same way. They multiply rather than cancel.

Plumbing drawings →
No cost, no obligation

Planning a Home in Coimbatore?

Bring your supply interval. Household size, plot dimensions and how often water actually reaches your street — those three settle the sump, and the sump position shapes the plan around it. Across Chennai and Coimbatore.

Contact Buildiyo →

Ask the street before you ask the chart

Sump sizing looks like arithmetic and is mostly local knowledge. Only one number in it is exact — a cubic metre is a thousand litres. The per-person figure is a published band that has to be matched to your city rather than copied from the nearest guide, and the multiplier that dominates the answer, how long you must last between refills, is not written down anywhere and changes from one street to the next. So find the interval out first, at its worst rather than its usual. Take the per-person figure from the band that fits your city. Do the multiplication second, choose the reserve deliberately rather than by rounding to a familiar capacity, and settle the whole thing while the plan can still move.

Four numbers to settle before the plan is fixed

Three are judgements, one is exact
1

The per-person figure from the band that fits your city, checked against the state minimum rather than defaulted to 135.

2

The worst supply interval anyone on your street reports, including what happens in a dry spell.

3

The reserve margin, chosen for a stated reason rather than produced by rounding the answer to a stock tank size.

4

The effective internal volume in cubic metres, with freeboard and wall thickness outside it, agreed with your engineer.